Fibrecat s80 messages – FUJITSU CentricStor V3.1D User Manual
Page 488
488
U41117-J-Z125-7-76
Message lines
Explanation of console messages
SXRD104
WARNING: raid 0:1:0 - Disk: Write-Only, 17300 MB
Meaning
A rebuild is active for the physical disk of controller 0, channel 1, target ID 0.
9.2.15.2
FibreCAT S80 messages
SXRD00
s80d: RAID:
Meaning
If there is a status change in a S80 component, a message will be output on the console.
The terms used here have the following meanings:
n
1 - 8
weight
Error severity:
NOTICE
information
n=8,9
WARNING
soft error
n=6,7
ERROR
error
n=4,5
ALERT
critical error
n=2,3
raid-id
FibreCAT identification (target# of the 2 RAID controllers)
raid#
Number of the RAID system (1 – 8)
shelf#
Number of the shelf (1 – 7)
component
Internal component of the shelf
Disk drive (1 – 14)
Power supply (1 – 2)
Cooling fan (1 – 4)
Enclosure services module (1 – 2)
Loop monitor
Voltage sensor (1 – 6)
Current sensor (1 – 6)
Temperature sensor (1 – 4)
status
Status of the component
OK
Error corrected
Warning
Non-critical error (sensor only)
Critical
Critical error
Not Installed
Component removed or faulty
Not Available
Component not in operation
Unknown
Status not available (sensor only)