FUJITSU CentricStor V3.1D User Manual
Page 457
U41117-J-Z125-7-76
457
Explanation of console messages
Message lines
SXIB200
IB 200 NOTICE "Please archive the performance history log files."
Response
If performance analyses are required for periods which precede the recording period, the
history log files from the [fsys]/apc/diag/emtape/hist_log directory must be archi-
ved. Obsolete performance history log files are automatically deleted after the recording pe-
riod has elapsed .
SXIB201
IB 201 WARNING "Performance history recording discontinued."
Meaning
It is not possible to continue writing the history data (permanent or temporary problem).
Cause: may be a write error, hard disk is full, too many processes in the system, among
other things.
SXIB202
IB 202 NOTICE "Performance history recording resumed."
Meaning
If the situation indicated by IB201 was temporary, recording of history data is continued.
In the history data there will be a time gap between message IB201 and IB202.
SXIB300
IB(#300): ERROR: connection to
Meaning
The hosts of the CentricStor network are monitored using a “keep-alive” mechanism. Here
the hosts must report regularly to the network by means of “sign-of-life” messages. If the
above message appears this means that the host specified with
“sign-of-life” message for more than 10 seconds. It can be assumed that the host is no
longer available. This message also occurs in poor or overloaded networks or if the
monitoring software on the host has been stopped. However, if neither is the case, this
means that the host has been shut down or has crashed.
Response
Notify maintenance staff.
SXIB400
IB(#400) ALERT: Distr. & Act.: vtls_spray: cmd "
Meaning
During a “Distribute and Activate” the vtls_spray.sh script encountered an error in the
command
Response
Check why the command
SXIB500
VLP0 : IB(#500) ERROR
Meaning
The FC switch does not respond to SNMP requests.