7.1 RMON-specific Buttons

The RMON window is slightly different from the MIB variable windows. The RMON window has
several tabs and each tab has the following tool buttons in addition to the buttons in the MIB variable
windows.

Absolute Value

Displays collected data as they are.

Per Sample

Displays the difference between the last two sampled values. The value is rounded.

Per Second

Displays the difference between the last two sampled values per second. This is (Current
value - Previous value) / Polling Interval. The value is rounded.

Start Polling

Restarts polling.

Stop Polling

Pauses polling. This may be useful for examining current data carefully.

Refresh

Forces immediate polling and displays the latest sampled value regardless of the regular
polling timer.

7 RMON

PN 613-50664-00 Rev A

Page 85 of 127