The owner (creator) of the Alarm entry. By default, "AT-View Plus Device Manager
- station name" is used where "station name" represents the host name of the station
on which AT-View Plus Device Manager is running.

Startup Alarm Type

The type of threshold which is applied to the first sampled value after this Alarm
entry becomes valid.

rising alarm

A single RMON event is triggered if the first sampled value is greater than or
equal to the configured rising threshold.


falling alarm

A single RMON event is triggered if the first sampled value is less than or
equal to the configured falling threshold.


rising or falling alarm

A single RMON event is triggered if the first sampled value is greater than or
equal to the configured rising threshold, or if the first sampled value is less
than or equal to the configured falling threshold.

Note

- The Startup Alarm Type is only applied to the first sampled value. From the second

sampled value, both the rising and falling thresholds are effective regardless of the Startup
Alarm Type. If only one type of threshold is significant, set the "Event Index" for the Alarm
type that is not required to 0. For example, if you want to monitor only the rising threshold,
set the Falling Event Index to 0. No event occurs for an Event Index of 0, even if the values
reach the threshold.

Rising Alarm Event Rule

Configuration for the rising alarm. If you select "falling alarm" for the Startup Alarm Type,
only "Rising Threshold" and "Rising Event Index" can be configured. If there is no Event
entry corresponding to the Event Index, no event will occur.

Rising Threshold

The ceiling threshold. If the monitored variable exceeds this threshold, the rising
alarm is invoked. The default is 3000.

Event Type

The type of action to be taken when the event occurs. Select one of "none" (no action
taken), "SNMP trap" (send out an SNMP trap), "log" (record to the log) and "log &
SNMP trap" (record to the log and send out an SNMP trap).

Rising Event Index

Index of the RMON Event entry which is triggered when the sampled value reaches
the rising threshold. If you select "falling alarm" for the Start Alarm Type, this

PN 613-50664-00 Rev A

Page 119 of 127