3 regist menu, 4 save polling data, Regist menu – Allied Telesis AT-VIEW PLUS 3.0 DEVICE MANAGER User Manual
Page 111: Save polling data
Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGER
Absolute Value
Displays the sum of values which AT-View Plus Device Manager got from the RMON
agents, as shown in the following example.
Data sampled by RMON Data displayed by AT-View Plus
Device Manager
Sample 1 100
100
Sample 2 50
150
Sample 3 250
400
Per Sample
Displays data which AT-View Plus Device Manager got from the RMON agent as it is.
Data sampled by RMON
Data displayed by AT-View Plus
Device
Manager
Sample 1 100
100
Sample 2 50
50
Sample 3 250
250
Per Second
Displays "Sampled data / Sampling Interval configured on the RMON agent". The sampling
interval here is the RMON agent's sampling interval, not the interval configured in AT-View
Plus Device Manager. In the following example, the RMON agent's sampling interval is 10
seconds.
Note
- Calculated values are rounded. For example, the Number of Error packets is usually
very small so that the calculated value is likely to be zero.
Data sampled by RMON Data displayed by AT-View Plus
Device
Manager
Sample 1 100 10 (100 / 10)
Sample 2 50 5 (50 / 10)
Sample 3 250 25 (250 / 10)
7.3.7.3 Regist Menu
Add this window to the user-defined User Menu.
7.3.7.4 Save Polling Data
This button opens the Polling Data Save dialog box, used to save collected data to a file. Specify the
name and format of the file in which the data is to be saved. Select a file format from the options
below. To start saving the data, click OK.
When you start saving data, the button's label changes to "Saving polled data". To close the file and
stop saving the data, click the "Saving polled data" button.
CSV Format
Saves the data in comma-separated values (CSV) format.
PN 613-50664-00 Rev A
Page 111 of 127