Allied Telesis AT-S63 User Manual
Page 148

Chapter 11: Event Logs and Syslog Servers
148
Section II: Advanced Operations
The Create Log Output page is shown in Figure 41.
Figure 41. Create Event Log Output Page
5. Configure the following parameters as necessary:
Output ID
Specifies an identification number for the syslog output definition.
Each definition must be given a unique number. The range is 2 to 20.
The default is the next available number.
Output Status
Controls the status of the syslog output definition. The options are:
Enabled - Enables the output definition. The switch uses the output
definition to send events to the syslog server.
Disabled - Disables the log output. The switch does not use the output
definition.
Message Format
Controls the format of the sent event messages. The options are:
Extended - Sends the time, module, severity, description, file name,
line number, and event ID. This is the default.
Normal - Sends the time, module, severity, and description for each
event.
Severity Selections
Specifies the severity of events to be sent to the syslog server. The
options are:
ALL - Sends all event messages of the following types. Use Ctrl key to
select more than one severity. This is the default.