Expansion Module Notes
•
Expansion module ports cannot be enabled/disabled. Attempting to do so will result
in the error message: "The error occurred with 'Set' operation. Error: gen Error".
•
The Port Speed and Mode parameter of the 100/1000Base-T port on the AT-A14
expansion module can only be set to 'auto'. Attempting to set this to any other value
will result in the error message: "The error occurred with 'Set' operation. Error: gen
Error".
•
A GBIC image is always visible on the GBIC slot of the AT-A15 expansion module
even if there is no GBIC physically inserted.
•
The Port Speed and Mode parameter of the 1000Base-X port on the AT-A15
expansion module can only be set to '1Gbps full-duplex'. Attempting to set this to
any other value will result in the error message: "The error occurred with 'Set'
operation. Error: gen Error".
•
The Port Speed and Mode parameter of the 100Base-FX port on the AT-A16, AT-
A17, and AT-A19 expansion modules can only be set to '100Mbps full-duplex'.
Attempting to set this to any other value will result in the error message: "The error
occurred with 'Set' operation. Error: gen Error".
AT-8324