Note
-
The current firmware version does not allow the Port State parameter to be
set to 'enabled'. Attempting to do so will result in the error message: "The error
occurred with 'Set' operation. Error: bad value." To enable a port, click on the
Enable option under the Port menu.
Note
-
4 ports are allotted for each expansion module slot. This means that ports on
expansion modules will always be numbered starting from 25 if inserted in Slot A
and from 29 if inserted in Slot B. As a result, the Detail Info MIB variable window for
port numbers that do not have corresponding physical ports on the expansion
module inserted will display 'noSuchName.' for all parameters.
Enable
Enables the port.
Note
-
The current firmware version (AT-S25 v2.0.2) supports atiStackSwitch.mib
v1.0 while Device Manager supports atiStackSwitch.mib v2.13. In v1.0, the Port State
parameter has 6 possible states with the enabled state having an ordinal value of 3.
In v2.13, the Port State parameter has only 2 possible states with the enabled state
having an ordinal value of 1. Since Device Manager continues to use the ordinal value
3, which does not exist in v2.13, the confirmation message will appear as "May I set
up 'atiStkSwPortState.x.y' to '???(3)'?" However, clicking on the OK button will still
enable the port successfully. This is because the actual Set operation is performed
on the device whose firmware supports v1.0 and thus, recognizes the ordinal value 3.
Disable
Disables the port.
Port Mirroring
Displays port mirroring parameters and allows configuration of port mirroring state,
source, and destination.