Device Info
Displays device information such as the application version, hardware version and
vendor information.
User Info
Displays user information such as the Configuration rights, Access and Password.
Note
- If the user account used to connect to the AT-RG600 device has write but no
read access to a supposedly configurable MIB variable under the User Info sub-menu
option, a checkbox will not be displayed for that MIB variable. Since no checkbox is
displayed, the user account will not be able to change the value of that MIB variable.
Note
- AT-RG613TX: The current firmware version accepts up to 85 characters for
the Comment parameter. Attempting to enter more than 85 characters will cause
the device to restart and will eventually result in the error message: "The error
occurred with 'Set' operation. Error: Time out occurred."
Note
- AT-RG613xx/AT-RG644B: The current firmware version accepts up to 79
characters for the Password parameter. Attempting to enter more than 79
characters will cause the device to restart and will eventually result in the error
message: "The error occurred with 'Set' operation. Error: Time out occurred."
Note
- AT-RG634A: The current firmware version accepts up to 88 characters for
the Comment parameter. Attempting to enter more than 88 characters will cause
the device to restart and will eventually result in the error message: "The error
occurred with 'Set' operation. Error: Time out occurred." The Comment parameter
will then return to its default value. If GSPAN firmware is used, the same behavior
may occur if the Comment parameter is set to a string value of length greater than
65 characters.
Note
- AT-RG634A: The current firmware version accepts up to 87 characters for
the Password parameter. Attempting to enter more than 87 characters will cause
the device to restart and will eventually result in the error message: "The error
occurred with 'Set' operation. Error: Time out occurred." The Password parameter
will then return to its default value. If G-SPAN firmware is used, the same behavior
may occur if the Password parameter is set to a string value of length greater than
84 characters.
Note
- AT-RG656BD: Valid MIB Set values for the Comment parameter are in the
range [0-89] inclusive. Attempting to set this parameter to a value outside the valid
range will cause the device to restart and will eventually result in the error message:
"The error occurred with 'Set' operation. Error: Time out occurred."
Note
- AT-RG656BD: Valid MIB Set values for the Password parameter are in the
range [0-75] inclusive. Attempting to set this parameter to a value outside the valid
range will cause the device to restart and will eventually result in the error message:
"The error occurred with 'Set' operation. Error: Time out occurred."