User-n, Output ), Utput – Red Lion PAX2D User Manual

Page 17: Arameters, Setpoint output parameters ( setpnt ), Output, Select, Assign, Logic, Action

background image

17

OUtPUt

SEtPNt

SELECt

S1

SPt

Setpoint

Select

ASSIGN

NONE

S

n

Setpoint

Assignment

LOGIC

NOr

S

n

Output

Logic

ACtION

NO

S

n

Setpoint

Action

Annun

NOr

S

n

Setpoint

Annunciator

Color

NO CHG

S

n

Line 1 Change

Color

SEtPNt

100

S

n

Setpoint

Value

trAC

NO

S

n

Setpoint

Tracking

tYPE

HI-ACt

S

n

Activation

Type

P-UP

OFF

S

n

Output Power-up

State

n = Setpoint Number (1-4)

StbY

NO

S

n

Setpoint

Standby

Operation

t-ON

0.00

S

n

Off Time

Delay

HYSt

0

S

n

Hysteresis

Value

t-OFF

0.00

S

n

On Time

Delay

t-OUt

1.00

S

n

Output

Time-out

Value

1-SHOt

NO

S

n

Rate Timed

Output One-Shot

Mode

AUtO

NO

S

n

Counter

Auto Reset

RESEt

NO

S

n

Output Reset

With Counter

Reset

RSt-Sn

NO

S

n

Output Reset

at Sn+1

Pro

OUtPUt

Pro

NO

F1

F2

P

D

O

uTpuT

p

arameTers

(OUtPUt)

SETPOINT OUTPUT PARAMETERS (SEtPNt)

This section details the programming for the setpoints. To have output capabilities, a setpoint Plug-in card needs to be installed into the PAX2D (see Ordering

Information). Depending on the card installed, there will be two or four setpoint outputs available. If no output card is installed, programming for the setpoints is still

available. An Exchange Parameter Lists feature for setpoint values is explained in User Input programming. For maximum input frequency, unused setpoints should

be configured for NO action.

The Setpoint Assignment and Setpoint Output Action determine setpoint feature availability. The Setpoint Parameter Availability chart illustrates this.

SETPOINT DEACTIVATE (RESET) MOMENTARY (EDGE)

When activated (momentary action), the meter deactivates (resets) the

setpoint outputs configured as YES in the sublist.

DISPLAY

DESCRIPTION

FACTORY

S1

Setpoint 1

NO

S2

Setpoint 2

NO

S3

Setpoint 3

NO

S4

Setpoint 4

NO

SETPOINT ACTIVATE (SET) MAINTAINED (LEVEL)

The meter activates (sets) the setpoint outputs configured as YES in the

sublist, as long as activated (maintained action).

DISPLAY

DESCRIPTION

FACTORY

S1

Setpoint 1

NO

S2

Setpoint 2

NO

S3

Setpoint 3

NO

S4

Setpoint 4

NO

SETPOINT ACTIVATE (SET) MOMENTARY (EDGE)

When activated (momentary action), the meter activates (sets) the setpoint

outputs configured as YES in the sublist.

DISPLAY

DESCRIPTION

FACTORY

S1

Setpoint 1

NO

S2

Setpoint 2

NO

S3

Setpoint 3

NO

S4

Setpoint 4

NO

HOLD SETPOINT STATE

The meter holds the state of the setpoint outputs configured as YES in the

sublist, as long as activated (maintained action).

DISPLAY

DESCRIPTION

FACTORY

S1

Setpoint 1

NO

S2

Setpoint 2

NO

S3

Setpoint 3

NO

S4

Setpoint 4

NO

USEr-n

SPr-E

USr

Fn

SPr-E

FNC

USEr-n

SPS-L

USr

Fn

SPS-L

FNC

USEr-n

SPS-E

USr

Fn

SPS-E

FNC

USEr-n

SPHOLd

USr

Fn

SPHOLd

FNC

OUTPUT SELECT

SEtPNt

ANALOG

Select the Setpoint or Analog output to be programmed. The Analog output selection

only appears if an analog output plug-in card is installed in the meter.

OUtPUt

SEtPNt

SETPOINT PARAMETER AVAILABILITY

PARAMETER

DESCRIPTION

COUNTER ASSIGNMENT

RATE ASSIGNMENT

TIMED OUT

t-OUt

BOUNDARY

bOUNd

LATCH

LAtCH

TIMED OUT

t-OUt

BOUNDARY

bOUNd

LATCH

LAtCH

LOGIC

Setpoint Output Logic

Yes

Yes

Yes

Yes

Yes

Yes

Annun

Setpoint Annunciator

Yes

Yes

Yes

Yes

Yes

Yes

Color

Setpoint Line 1 Color

Yes

Yes

Yes

Yes

Yes

Yes

SEtPNt

Setpoint Value

Yes

Yes

Yes

Yes

Yes

Yes

trAC

Setpoint Tracking

Yes

Yes

Yes

Yes

Yes

Yes

P-UP

Setpoint Output Power-up State

No

No

Yes

No

No

Yes

tYPE

Setpoint Activation Type

No

Yes

No

Yes

Yes

Yes

StbY

Standby Operation

No

Yes

No

Yes

Yes

Yes

HYSt

Setpoint Hysteresis

No

No

No

Yes

Yes

No

t-ON

Setpoint On Time Delay

No

No

No

Yes

Yes

Yes

t-OFF

Setpoint Off Time Delay

No

No

No

No

Yes

No

t-OUt

Setpoint Output Time-out Value

Yes

No

No

Yes

No

No

1-SHOt

Rate Timed Output One-shot

No

No

No

Yes

No

No

AUtO

Counter Auto Reset

Yes

No

Yes

No

No

No

RESEt

Output Reset with Manual Reset

Yes

No

Yes

No

No

No

RSt-Sn

Setpoint Output Reset at Sn+1

Yes

No

Yes

No

No

No