User-n, Output ), Utput – Red Lion PAX2D User Manual
Page 17: Arameters, Setpoint output parameters ( setpnt ), Output, Select, Assign, Logic, Action

17
OUtPUt
SEtPNt
SELECt
S1
SPt
Setpoint
Select
ASSIGN
NONE
S
n
Setpoint
Assignment
LOGIC
NOr
S
n
Output
Logic
ACtION
NO
S
n
Setpoint
Action
Annun
NOr
S
n
Setpoint
Annunciator
Color
NO CHG
S
n
Line 1 Change
Color
SEtPNt
100
S
n
Setpoint
Value
trAC
NO
S
n
Setpoint
Tracking
tYPE
HI-ACt
S
n
Activation
Type
P-UP
OFF
S
n
Output Power-up
State
n = Setpoint Number (1-4)
StbY
NO
S
n
Setpoint
Standby
Operation
t-ON
0.00
S
n
Off Time
Delay
HYSt
0
S
n
Hysteresis
Value
t-OFF
0.00
S
n
On Time
Delay
t-OUt
1.00
S
n
Output
Time-out
Value
1-SHOt
NO
S
n
Rate Timed
Output One-Shot
Mode
AUtO
NO
S
n
Counter
Auto Reset
RESEt
NO
S
n
Output Reset
With Counter
Reset
RSt-Sn
NO
S
n
Output Reset
at Sn+1
Pro
OUtPUt
Pro
NO
F1
F2
P
D
O
uTpuT
p
arameTers
(OUtPUt)
SETPOINT OUTPUT PARAMETERS (SEtPNt)
This section details the programming for the setpoints. To have output capabilities, a setpoint Plug-in card needs to be installed into the PAX2D (see Ordering
Information). Depending on the card installed, there will be two or four setpoint outputs available. If no output card is installed, programming for the setpoints is still
available. An Exchange Parameter Lists feature for setpoint values is explained in User Input programming. For maximum input frequency, unused setpoints should
be configured for NO action.
The Setpoint Assignment and Setpoint Output Action determine setpoint feature availability. The Setpoint Parameter Availability chart illustrates this.
SETPOINT DEACTIVATE (RESET) MOMENTARY (EDGE)
When activated (momentary action), the meter deactivates (resets) the
setpoint outputs configured as YES in the sublist.
DISPLAY
DESCRIPTION
FACTORY
S1
Setpoint 1
NO
S2
Setpoint 2
NO
S3
Setpoint 3
NO
S4
Setpoint 4
NO
SETPOINT ACTIVATE (SET) MAINTAINED (LEVEL)
The meter activates (sets) the setpoint outputs configured as YES in the
sublist, as long as activated (maintained action).
DISPLAY
DESCRIPTION
FACTORY
S1
Setpoint 1
NO
S2
Setpoint 2
NO
S3
Setpoint 3
NO
S4
Setpoint 4
NO
SETPOINT ACTIVATE (SET) MOMENTARY (EDGE)
When activated (momentary action), the meter activates (sets) the setpoint
outputs configured as YES in the sublist.
DISPLAY
DESCRIPTION
FACTORY
S1
Setpoint 1
NO
S2
Setpoint 2
NO
S3
Setpoint 3
NO
S4
Setpoint 4
NO
HOLD SETPOINT STATE
The meter holds the state of the setpoint outputs configured as YES in the
sublist, as long as activated (maintained action).
DISPLAY
DESCRIPTION
FACTORY
S1
Setpoint 1
NO
S2
Setpoint 2
NO
S3
Setpoint 3
NO
S4
Setpoint 4
NO
USEr-n
SPr-E
USr
Fn
SPr-E
FNC
USEr-n
SPS-L
USr
Fn
SPS-L
FNC
USEr-n
SPS-E
USr
Fn
SPS-E
FNC
USEr-n
SPHOLd
USr
Fn
SPHOLd
FNC
OUTPUT SELECT
SEtPNt
ANALOG
Select the Setpoint or Analog output to be programmed. The Analog output selection
only appears if an analog output plug-in card is installed in the meter.
OUtPUt
SEtPNt
SETPOINT PARAMETER AVAILABILITY
PARAMETER
DESCRIPTION
COUNTER ASSIGNMENT
RATE ASSIGNMENT
TIMED OUT
t-OUt
BOUNDARY
bOUNd
LATCH
LAtCH
TIMED OUT
t-OUt
BOUNDARY
bOUNd
LATCH
LAtCH
LOGIC
Setpoint Output Logic
Yes
Yes
Yes
Yes
Yes
Yes
Annun
Setpoint Annunciator
Yes
Yes
Yes
Yes
Yes
Yes
Color
Setpoint Line 1 Color
Yes
Yes
Yes
Yes
Yes
Yes
SEtPNt
Setpoint Value
Yes
Yes
Yes
Yes
Yes
Yes
trAC
Setpoint Tracking
Yes
Yes
Yes
Yes
Yes
Yes
P-UP
Setpoint Output Power-up State
No
No
Yes
No
No
Yes
tYPE
Setpoint Activation Type
No
Yes
No
Yes
Yes
Yes
StbY
Standby Operation
No
Yes
No
Yes
Yes
Yes
HYSt
Setpoint Hysteresis
No
No
No
Yes
Yes
No
t-ON
Setpoint On Time Delay
No
No
No
Yes
Yes
Yes
t-OFF
Setpoint Off Time Delay
No
No
No
No
Yes
No
t-OUt
Setpoint Output Time-out Value
Yes
No
No
Yes
No
No
1-SHOt
Rate Timed Output One-shot
No
No
No
Yes
No
No
AUtO
Counter Auto Reset
Yes
No
Yes
No
No
No
RESEt
Output Reset with Manual Reset
Yes
No
Yes
No
No
No
RSt-Sn
Setpoint Output Reset at Sn+1
Yes
No
Yes
No
No
No