Vaisala AWS330 User Manual
Page 289

Appendix B ______________________________________________________ Calculation Formulas
VAISALA ______________________________________________________________________ 287
Wind Speed (U
2
)
Estimate wind speed at 2 m height when measured at height z.
−
=
)
42
.
5
)
8
.
67
ln((
87
,
4
2
z
U
U
z
where
Uz
= Wind speed measured at height z [ms
-1
]
z
= Height of wind speed measurement [m]
Vapor Pressure Deficit (e
a
-e
d
)
−
+
=
−
=
d
a
a
d
a
e
T
e
T
e
e
e
VPD
2
)
(
)
(
)
(
min
max
where
e
a
= Saturation vapor pressure [kPa]
e
d
= Actual vapor pressure [kPa]
+
=
3
.
237
27
.
17
exp
611
.
0
)
(
max
max
max
T
T
T
e
a
+
=
3
.
237
27
.
17
exp
611
.
0
)
(
min
min
min
T
T
T
e
a
+
=
100
)
(
2
1
100
)
(
2
1
min
max
max
min
RH
T
e
RH
T
e
e
a
a
d
where
T
max
=
Maximum daily temperature [
°
C]
T
min
=
Minimum daily temperature [
°
C]
e
a
(T
max
) = Saturation vapor pressure at T
max
e
a
(T
min
) = Saturation vapor pressure at T
min
e
d
(T
max
) = Actual vapor pressure at T
max
e
d
(T
min
) = Actual vapor pressure at T
min
RH
max
= Maximum daily relative humidity [%]
RH
min
= Minimum daily relative humidity [%]