Battery regulator qbr101c – Vaisala AWS330 User Manual
Page 251

Chapter 8 ____________________________________________________________ Technical Data
VAISALA ______________________________________________________________________ 249
Battery Regulator QBR101C
Table 83
Battery Regulator QBR101C Specifications
Property Description/Value
Maximum input voltage (DCin,
SOL1, SOL2)
30 VDC
Maximum input current (DCin)
6 A
Solar panel input (SOL1, SOL2)
12 V panels only
Recommended input voltage to
DCin
16 VDC
Max. load current (backup output) 3.5 A
Recommended battery capacity
range
4 … 72 Ah
Battery charge current limit
0.5/1.0/1.5/2.0/2.5 A (jumper selectable)
AWS330 selection: 2.5 A
Max. battery discharge current
3.5 A
Battery charge voltage selection
(with external resistor)
13.7 V for standby use (AC backup)
14.4 V for cycling use (solar panels)
Temperature compensation for
charge voltage
-20 mV/
°
C typ.
Load disconnection threshold
voltage (at DCout/Switch)
10.0 V typ.
Load reconnection threshold
voltage (at DCout/Switch)
12.0 V typ.
Btry Low signal threshold voltage
11.5 V typ.
Self-consumption from battery
(with LEDs disconnected)
0.3 mA max. @ +25
°
C
Ground connection
GND connected to frame
Reverse voltage protection
Btry, solar panel
Dimensions (w
×
d
×
h)
90
Ч
80
Ч
25 mm
Weight 0.1
kg
Housing
Anodized aluminum, gray
Wire terminals
Battery and load wires
Solar panel, DC input, and
controls
Screw terminals, removable
2.5 mm
2
1.5 mm
2
Operating temperature range
-50 ... +60
°
C
MTBF (parts stress method,
MIL-HDBK-271F ground benign Ta
+25
°
C)
>150 000 hours