AC (Mains) Powering
For AC (mains) powering, make sure the site has been prepared
according to the instructions in section Site Preparation on page 35.
Before connecting the AC (mains) power cable, ensure there is no power
connected to the cable (by turning down the fuse or turning off the
power). Connect the AC (mains) power cable to the Mains Input
connector on bottom of the enclosure; see Figure 51 on page 95. Turn on
the AC power.
A 2-meter AC (mains) cable (item: DRW228770Z2M) is provided with
AWS330 when mains power supply is used.
1206-047
Figure 56
Screw Terminal Connections for AC (Mains) Power
Cable
Table 20
AC (Mains) Power Cable Specifications
Property Description/Value
Cable type
3x0.75 mm
2
H05RN-F
Connector
Female 3+PE Amphenol ECOMATE
Circular