Operating local lcd display qmd202 – Vaisala AWS330 User Manual
Page 167

Chapter 5 __________________________________________ Software Configuration and Operation
VAISALA ______________________________________________________________________ 165
Operating Local LCD Display QMD202
The optional Local LCD display QMD202 provides views for instant
measurements and basic system information. QMD202 is located inside
the enclosure. Navigate between the views by pressing the buttons on the
display.
NOTE
QMD202 is an optional device in AWS330 configuration, and is present
as ordered.
In addition to measured values, all observation displays contain
corresponding sensor status in the rightmost column. For sensor status
values, see section Sensor Status List on page 293.
1011-007
Figure 101 Meteorological Display 1
Table 46
Meteorological Display 1 Parameters
Heading Parameter
Unit
Statistic
Period
TA
Air temperature
°C
Average
1 min
RH
Relative humidity
%
Average
1 min
PA
Barometric pressure
hPa
Average
1 min
WD
Wind direction
Deg
Average
10 min
WS Wind
speed
m/s
Average
10
min
1011-008
Figure 102 Meteorological Display 2
Table 47
Meteorological Display 2 Parameters
Heading Parameter
Unit
Statistic
Period
PR Precipitation
mm
Sum 10
min
SR
Solar radiation
W/m2
Average
1 min