Vaisala wind vane wav151 – Vaisala AWS330 User Manual
Page 258

User's Guide ______________________________________________________________________
256 _________________________________________________________________ M211296EN-B
Vaisala Wind Vane WAV151
Table 99
Vaisala Wind Vane WAV151, Wind Direction
Property Description/Value
Measurement range at wind
speed 0.4 ... 75 m/s
0 ... 360°
Starting threshold
<0.4 m/s
Resolution ±2.8°
Damping ratio
0.19
Overshoot ratio
0.55
Delay distance
0.4 m
Table 100
Vaisala Wind Vane WAV151, General
Property Description/Value
Operating power supply
U
in
= 9.5 ... 15.5 VDC, 20 mA typical
Heating power supply
AC or DC 20 V, 500 mA nominal
Output code
6-bit parallel GRAY
Output levels
with
I
out
<+5 mA
High state > U
in
-1.5 V
with
I
out
>–5 mA
Low state < 1.5 V
Settling time after power
turn-on
<100 µs
Plug 10-PIN
MIL-C-26482 type
Cabling
10-wire cable through cross arm
Recommended connector at
cable end
SOURIAU MS3116F12-10P
Operating temperature with
heating
-50 ... +55 °C (-58 ... +131 °F)
Storage temperature
-60 ... +70 °C (-76 ... +158 °F)
Material
Housing
AlMgSi, gray anodized
Wave
Alsi 12 anodized
Dimensions
300 (h) Ч 90 (Ш) mm
Swept radius of vane
172 mm
Weight 660
g
Table 101
Vaisala Wind Vane WAV151, Test Compliance
Property Description/Value
Wind tunnel tests
ASTM standard method D5366-93 (for starting
threshold, distance constant, transfer function)
Exploratory vibration test
MIL-STD-167-1
Humidity test
MIL-STD-810E, Method 507.3
Salt fog test
MIL-STD-810E, Method 509.3
Complies with EMC standard EN61326-1:1997 + Am1:1998; Am2:2001;
Generic Environment