Resetting Calibration Numbers to Default
To completely reset all calibration numbers to their default settings, follow the
procedure below to completely remove power from and then restart the sta-
tion. When the station restarts, all default calibration values are restored.
Note: This resets all station information including highs/lows, barometric pressure, total rainfall, period infor-
mation, etc.
1. Write down the total rainfall, barometric pressure, and all alarm settings. You will
need to reenter these values later.
2. If desired, write down all highs, lows, daily rainfall, and period information. These val-
ues will be lost and cannot be restored.
3. Disconnect all power sources from the station, including the power adapter, battery
backup, solar power, etc.
All power must be removed from the unit.
4. Reattach the power adapter and insert the battery.
The unit will start up again and all CAL numbers will be reset to their
default values.
5. Re-enter the total rainfall, barometric pressure, and all alarm settings.
D
ISPLAY
S
CAN
The Energy EM comes with two pre-programmed scan routines which contin-
uously cycle through various displays. The short scan routine displays the cur-
rent value of every condition measured or calculated by the Energy EM. The
long scan routine displays the current value of every condition measured or
calculated and every high/low stored by the Energy EM. The long scan routine
does not show the times at which highs/lows were recorded.
Starting the Scan Routines
1. To start the short scan routine, press SCAN.
The unit begins to cycle through the short scan routine. Until you stop the
scan routine, it will continuously cycle through every condition measured or
calculated by the Energy EM.
2. To start the long scan routine, press SCAN again.
The unit begins to cycle through the short scan routine. Until you stop the
scan routine, it will continuously cycle through every condition measured or
calculated by the Energy EM and every high/low stored by the Energy EM.