The Terminal Box provides easy, reliable connections for splicing wires and
cables. All connections are housed in a weather-resistant enclosure. The termi-
nal box can simplify and speed up the task of wiring the weather station sen-
sors, sensor interface module (SIM), and communication lines.
Note:
The terminal blocks in the Terminal Box are rated for 300V, 10A and are intended for 26-16 AWG
(.08-1.5 mm) wire. When wiring, all applicable building and electrical codes must be followed.
When connecting shielded cables to shielded cables, connect each colored wire
to the same colored wire on the extension cable (or other cable). In twisted-pair
cables, all black wires are ground and may be shorted together.
When connecting standard cables to standard cables, you may also connect
each colored wire to the same colored wire on the extension cable (or other
cable). In some cases, however, wires may be combined in order to use fewer
terminals on the terminal block. Consult the table below:
S
ENSOR
W
IRES
IN
S
TD
. C
ABLE
W
IRES
U
SED
N
OTES
FOR
S
TANDARD
C
ABLES
Rain Collector
4
2
Twist RED and BLACK as one wire and GREEN and YELLOW as
another wire.
Temp/Hum Sensor
6
5
Twist RED and BLACK as one wire (ground).
Temp Sensor
4
2
Twist RED and BLACK as one wire (ground). Ignore GREEN.
UV/Leaf Wetness Sensor
6
3
Twist RED and BLACK as one wire (ground). Ignore GREEN and
BLUE.
Solar Radiation Sensor
4
3
Twist RED and GREEN as one wire (ground).
Anemometer
4
4
SIM/Junction Box Cable
8