Table 23 – HP StorageWorks XP Remote Web Console Software User Manual
Page 105

Table 23
Parameter
Restriction
Error Report
PRIMARY
Siz does not use the PRIMARY
parameter within the SUSPEND
command.
MSGREQ
This parameter cannot be used for
ICKDSF when the volume specified
as the S-VOL or T-VOL is used for
TCz.
When the volume specified as
the S-VOL is used for TCz, check
the pair status by executing the
QUERY command to the T-VOL.
If you specify the volume which is
shared with TCz and URz M-VOL
(P-VOL) as Siz S-VOL, and if the
pair status of the TCz pair is
Duplex, the job of the ESTPAIR
command will end normally before
the copying processing of the
Siz pair completes even when
YES is specified for the MSGREQ
parameter.
When the volume specified as
the T-VOL is used for TCz, check
the pair status by executing the
QUERY command to the S-VOL.
QUIESCE
This parameter cannot be used
when the disk controller emulation
type is 2105 or 2107. To use this
parameter, set the disk controller
emulation type to 3990.
In case of TSO, Siz ignores this
parameter.
In case of ICKDSF, the job ends
abnormally (CC=12).
ONLINESEC
Online check is not available
when you perform backward
resynchronization by the ICKDSF
command. If you specify NO for
this parameter, or if you do not
specify the parameter, an error
occurs whether the volume is
online or offline.
Although no error occurs when
you specify YES for this parameter,
note that the copying operation
is performed without any online
check.
In case of ICKDSF, the job ends
abnormally (CC=12).
Set Path
Siz does not use the Set Path
parameter.
Hitachi ShadowImage for z/OS user guide