Scsi physical drives – HP Insight Management Agents User Manual
Page 94
•
Backplane Speed—Displays the speed of the storage system backplane. The following values
are possible:
◦
Ultra3—The storage system is capable of Ultra3 speeds.
◦
Ultra320—The storage system is capable of Ultra320 speeds.
◦
Unknown—The Storage Agents are unable to determine the storage system backplane
speed. You might need to upgrade your software.
•
Drive Bays—Displays the number of drive bays provided by this storage system. If duplexing
hardware is used with the storage system, the drive bay number is less than the number of
physical drive bays in the enclosure.
•
Duplex Option—Displays the duplex option installed in this storage system. The following
values are possible:
◦
Duplex Top—This storage system is the top part of a duplexed unit.
◦
Duplex Bottom—This storage system is the bottom part of a duplexed unit.
◦
None—A duplex option is not installed.
•
Power Supply Status—Displays the status of the Redundant Power supply. The following values
are possible:
◦
OK—All component power supplies that make up the redundant power supply are in
normal working order.
◦
Degraded—One of the component power supplies that make up the redundant power
supply has failed. The drive system (either a drive subsystem or a power supply for the
main unit) continues to operate. However, if the remaining power supply should fail, the
drive system loses power and data loss could occur. To correct this situation, schedule a
time to bring the device down and replace the failed power supply.
◦
Unknown—The Storage Agents do not recognize the redundant power supply. You might
need to upgrade your software.
◦
No Redundant Power Supply—This ProLiant server does not support a redundant power
supply.
SCSI physical drives
Select a SCSI physical drive from the SCSI controller submenu to display the following information:
•
Status—Displays the status of the physical drive selected. The following values are valid:
OK—The physical drive is operating normally.
◦
◦
Failed—The physical drive has failed and can no longer return data. The drive might
need to be replaced.
◦
Not Configured—The physical drive is not configured. Ensure that all of the drive switches
are properly set.
◦
Bad Cable—A physical drive is not responding. Check the cables connected to the drive.
◦
Predictive Failure—One of the physical drive thresholds has been exceeded.
◦
Offline—The physical drive is offline and can no longer return data. No further status is
available.
◦
Missing was OK—A physical drive that was located in the system and had a status of
OK has been removed.
94
Agent information