beautypg.com

Temperature sensors information – HP Insight Management Agents User Manual

Page 114

background image

Temperature Sensors Information

Temperature condition—Displays the current temperature condition of the system or client PC.
This value can be:

OK—The temperature is within normal operating range.

Degraded—The temperature is above normal for airflow obstructions. Make sure that the
cover is on.

CAUTION:

Do not operate the system with the cover removed. Proper airflow is possible

only when the cover is in place and properly secured.

Failed—The temperature is outside the normal operating range and could permanently
damage the system. The system automatically shuts down to prevent damage to hardware
or data loss.

NOTE:

A Failed condition does not occur in a client PC since the power supply for the

client is cut off if thermal condition reaches a permanently damaging level.

Unknown— If the Server Agents or the Server Agent cannot determine the status of the
device, you may need to upgrade your driver software. If you are managing a client with
an unknown temperature status, the client may not support thermal detection.

Sensor—The number that uniquely specifies the temperature sensor description.

Location—This specifies the location of the temperature sensor present in the system.

Temperature—This is the current temperature sensor reading in degrees Celsius.

Threshold—This is the shutdown threshold temperature sensor setting in degrees Celsius. This
is the temperature at which the sensor is considered to be in a failed state causes the system
to be shutdown.

NOTE:

Only the Ambient zone type allows setting of the threshold temperature. Not all

(maybe one or none) sensors can set this value.

Type—This specifies the type of this instance of temperature sensor. This value can be:

Blowout—If a blowout temperature sensor reaches its threshold, the fan or fans in the
area of the temperature sensor increases in speed in an attempt to reduce the temperature
before a caution or critical threshold is reached.

Caution—If a caution temperature sensor reaches its threshold, the temperature condition
is set to degraded and the system either continues or shuts down depending on the setting
of the Thermal Degraded Action.

Critical—If a critical temperature sensor reaches its threshold, the Temperature Condition
is set to failed and the system shuts down.

Unknown—The Temperature threshold type could not be determined.

114

Agent information