HP Insight Management Agents User Manual
Page 68
•
Drive Bays displays the number of bays on this storage system backplane.
•
Temperature Status displays the current temperature status of the storage system backplane.
The following values are possible:
◦
OK - The temperature is within the normal operating range.
◦
Degraded - The temperature is outside of the normal operating range.
◦
Failed - The temperature has exceeded the safe operating temperature and could
permanently damage the storage system.
◦
Not Monitored - This storage system does not support temperature monitoring.
◦
Not Supported - This storage system does not support reporting the temperature status
through this storage system backplane. The temperature status is reported through the
first backplane on this storage system.
◦
Unknown - The Storage Agent is unable to determine the temperature status.
•
Placement indicates the location of the storage system backplane. The following values are
valid:
◦
Internal - The storage system backplane is located inside the external array storage system
chassis.
◦
External - The storage system backplane is located outside the external array storage
system chassis in an external storage system.
◦
Unknown - The Storage Agent could not determine the location of the storage system
backplane.
•
Power Supply Status displays the current status of the storage system backplane fault tolerant
power supply. The following values are possible:
◦
OK - The fault tolerant power supply is operating normally.
◦
Degraded - One of the redundant power supplies has failed. Replace the failed power
supply.
◦
Failed - All of the power supplies have failed. Replace the failed power supplies.
◦
Not Redundant - This storage system does not have a redundant power supply.
◦
Not Redundant (Power Supply 1 Missing) - This storage system does not have a redundant
power supply. The power supply in bay 1 is missing.
◦
Not Redundant (Power Supply 2 Missing) - This storage system does not have a redundant
power supply. The power supply in bay 2 is missing.
◦
Not Supported - This storage system does not support reporting fault tolerant power supply
status through this backplane. The fault tolerant power supply status is reported through
the first backplane on this storage system.
◦
Unknown - The Storage Agent is unable to determine the fault tolerant power supply
status.
•
Duplex Option displays the storage system backplane duplex option. The following values
are possible:
◦
Not Duplexed - This storage system is not duplexed.
◦
Duplex Top - This is the top portion of a duplexed storage system.
68
Agent information