Sub-system classification, Power subsystem – HP Insight Management Agents User Manual
Page 112
Sub-system Classification
Power Subsystem
This section displays information about the redundant power supplies. The following entries may
be displayed:
•
Location—Displays the bay where the power supply is located.
•
Condition—Displays the status of the power supply. The following values are possible:
OK—A power supply is installed and operating normally.
◦
◦
Failed—A power supply is installed and is no longer operating. Replace the power supply.
◦
Not Installed—Nothing is installed in this power supply bay.
◦
Unknown—The Server Agent is unable to determine if this storage system power supply
bay is occupied.
•
Serial Number—Displays the serial number of the power supply. This information can be used
for identification purposes.
•
Firmware Revision—Displays the firmware revision of the power supply.
•
Present—Represents whether the power supply is present in the chassis.
•
Status—Represents the status of the power supply in the chassis. The following values are
possible:
◦
No Error
◦
General Failure
◦
Bist Failure
◦
Fan Failure
◦
Temperature Failure
◦
Interlock Open
◦
EPROM Failed
◦
VREF Failed
◦
DAC Failed
◦
RAM Test Failed
◦
Voltage Channel Failed
◦
Orring Diode Failed
◦
Brownout
◦
Give Up On Startup
◦
NVRAM Invalid
◦
Calibration Table Invalid
◦
If the power supply is absent, the status is "Not Applicable"
112
Agent information