Change Continuous Access Journal options used by mirrors
Most Continuous Access Journal pair operations are performed on multiple pairs. This is done
using a journal or mirrors. You can change the following options that affect the pairs in a mirror:
•
Unit of Path Watch Time—establishes the unit of path watch time.
•
Path Watch Time—establishes the amount of time before a blocked path results in the mirror
being split.
•
Forward Path Watch Time—establishes whether to forward the Path Watch Time value of the
master journal to the restore journal.
•
Copy Pace—establishes the pace at which data is copied.
•
Transfer Speed—which specifies the speed for data transfer.
•
Delta Resync Failure—which specifies the processing that takes place in the event of a failure.
Prerequisite information
Please be aware of the following when changing mirror options:
•
mirror options can be changed on the primary storage system and secondary storage system.
•
To change mirror options, the status of the mirror is one of the following:
Initial
◦
◦
Active
◦
Stopped
◦
Hold
◦
Holding
◦
Hold(Failure)
•
The Transfer Speed option can be changed if the mirror’s status is Active, Hold, or Holding.
•
When changing options for multiple mirrors, you can leave some options unchanged by
entering or selecting no value. If you specify a value, it is applied to the selected mirrors.
To change options for a mirror
1.
In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Journal
Operation. The Journal Operation window displays.
2.
Click
to change the mode from View to Modify.
3.
Operate either of the following:
In the upper right list, right click the desired journal and then select Mirror > Change Mirror
Option.