HP XP P9500 Storage User Manual
Page 115
Table 19 RAID Manager error codes for Continuous Access Journal (continued)
Error content
Error code (SSB2)
Error code (SSB1)
A request of Cnt Ac-J Paircreate was rejected because the desired capacity
exceeded the charging capacity of the secondary system’s program product.
EA41
A request to delete or suspend a Cnt Ac-J pair was rejected because the
specified volume is used in the system that consists of multiple primary and
secondary systems.
EA8B
A request to create a Cnt Ac-J pair for the system that consists of multiple
primary and secondary systems was rejected because the microcode was
being replaced.
EA92
A request of Cnt Ac-J Paircreate was rejected because the volume specified
for the primary volume was initializing the pool of Thin Provisioning.
EA95
A request of Cnt Ac-J Paircreate was rejected because the desired capacity
exceeded the charging capacity of the primary system’s Cnt Ac-J. Check
the license capacity as well as the related program product.
EAA2
A request of Cnt Ac-J Paircreate was rejected because the desired capacity
exceeded the charging capacity of the secondary system’s Continuous
EAA3
Access Synchronous. Check the License capacity as well as the related
Program product.
A request of Cnt Ac-J Paircreate was rejected because the desired capacity
exceeded the charging capacity of the secondary system’s Cnt Ac-J. Check
the license capacity as well as the related program product.
EAA5
A request of Cnt Ac-J Paircreate was rejected because the desired capacity
exceeded the charging capacity of the primary system’s Continuous Access
EAA6
Synchronous. Check the license capacity as well as the related program
product.
A request of Cnt Ac-J Paircreate (journal suspend mode) was rejected
because the delta resync function was unsupported.
EAD0
A request of Cnt Ac-J Paircreate was rejected because the specified P-VOL
or S-VOL is in the process of having the capacity changed by Thin
Provisioning.
EAE5
The Cnt Ac-J pair cannot be deleted because the specified Cnt Ac-J volume
is used as the Continuous Access Synchronous pair and is working in the
EAE7
journal that was registered when the 2DC Cascade was set to Enable in the
Edit Journal Volume dialog box.
A request of Cnt Ac-J Paircreate was rejected because the discarding process
of zero data in the specified P-VOL or S-VOL is in progress by Thin
Provisioning.
EAEB
A request of Cnt Ac-J Paircreate (journal suspend mode) or Cnt Ac-J
Pairresync (journal resync mode) was rejected because the pair was in the
state that was unavailable to transit.
EAF6
The Cnt Ac-J pair for the delta resync operation cannot be created because
the specified Cnt Ac-J S-VOL is in either one of the following statuses:
EB24
•
The volume cannot be used as the Cnt Ac-J volume for the delta resync
operation.
•
The status of the Cnt Ac-J pair is other than PAIR.
The Cnt Ac-J pair for delta resync operation cannot be created because the
specified Cnt Ac-J S-VOL is in either one of the following statuses:
EB25
•
The volume cannot be used as the Cnt Ac-J volume for the delta resync
operation.
•
The status of the Cnt Ac-J pair is the status other than PAIR or SUSPEND.
Troubleshooting using RAID Manager
115