beautypg.com

HP XP P9500 Storage User Manual

Page 117

background image

Table 19 RAID Manager error codes for Continuous Access Journal (continued)

Error content

Error code (SSB2)

Error code (SSB1)

A request was rejected by either of the following reasons:

EB60

The volume capacity of P-VOL was does not conform with the volume
capacity of S-VOL.

Capacities of each volumes that are concatenated in LUSE on the primary
site does not conform with capacities of each volumes that are
concatenated in LUSE on the secondary site.

A request of Cnt Ac-J Paircreate was rejected because the path between
the primary and the secondary systems was not valid.

EB61

A request of Cnt Ac-J Paircreate was rejected because the specified P-VOL
was a command device.

EB62

A request of Cnt Ac-J Paircreate was rejected because the restore journal
was already linked with another journal.

EB63

A request of Cnt Ac-J Paircreate was rejected because the desired capacity
exceeded the charging capacity of the program product.

EB64

A request of Cnt Ac-J Paircreate was rejected because of the abnormal end
which is related to the charging capacity of the program product.

EB65

The command was rejected and the retry processing was ordered because
P-VOL SUSPENDING was detected when the RAID Manager horctakeover
(resync) command was executed.

EB66

The Cnt Ac-J pair create processing was doubly executed:

EB6C

There are no problems if the initial copy operation is restarted when the
primary storage system is powered off.

There are no problems if a Cnt Ac-J pair is created when the primary
storage system is reset.

A request of Cnt Ac-J Paircreate was rejected because the Cnt Ac-J program
product was not installed in the primary system.

EB6E

The Cnt Ac-J pair cannot be created because the specified S-VOL is assigned
to a copy pair of other program products.

EB70

The Cnt Ac-J pair cannot be created because the specified S-VOL is the
system disk.

EB73

A request of Cnt Ac-J Paircreate was rejected because the journal cache of
the restore journal was remained.

EB7A

The Cnt Ac-J pair cannot be created because the specified S-VOL is an
external volume.

EB7D

The Cnt Ac-J pair cannot be created because of one of following:

EB7E

The specified S-VOL is being used by a Business Copy pair.

The specified S-VOL is a reserved volume.

A request of Paircreate was rejected because the emulation type of the
specified S-VOL was unsupported.

EB7F

The command was rejected because the specified volume was the V-VOL
or the pool-VOL. Please check the status of the volume.

EB80

A request of Cnt Ac-J Paircreate was rejected because the path from the
secondary system to the primary system was not set, or the S-VOL was in
the SMPL status.

EB87

Troubleshooting using RAID Manager

117