beautypg.com

Miscellaneous troubleshooting, Suspension among journals – HP XP P9500 Storage User Manual

Page 121

background image

Table 20 SIM reference codes, types, and descriptions (continued)

SVP log
file

System generating the
SIM

Description

Severity

Reference code

Byte 23

Byte 22

A failure has been detected in the
secondary system.

Primary
storage
system

Yes, repeatedly.

A volume being used by P-VOL of the Cnt
Ac-J Z pair for delta resync operation has
been suspended.

Serious

9X

DC

A failure has been detected in the primary
storage system.

SIM Log

Primary storage
system

A volume used in a P-VOL that is
configured in a multiple primary and

Serious

AX

DC

secondary system combination has been
suspended.

A failure has been detected in other
primary and secondary systems.

Notes:

If the DKC emulation type is 2105 or 2107, the setting of the system option mode 308 determines whether the SIM
is reported to the host, as explained below:

When system option mode 308 is set to ON, the SIM is reported to the host.

When system option mode 308 is set to OFF, the SIM is not reported to the host. By default, system option mode
308 is set to OFF.

Miscellaneous troubleshooting

Suspension among journals

All the journals in a consistency group can be suspended when an error occurs in one journal.
This takes place under the following conditions:

The Continuous Access Journal system consists of multiple primary and secondary systems

The status of the failed journal is PJSE or PJSF.

At least one journal in the consistency group is in normal status.

The communications line between the RAID Manager and all primary systems are normal.

The following is provided for your information when the circumstances above are present:

When an error occurs, the status of the journal changes from normal to PJSE (suspended by
error).

For an error caused by overflowing capacity, status changes to PJSF.

When one journal becomes PJSE or PJSF, all other normal journals in PJNN status also become
PJSE status.

If you use RAID Manager and if a journal is in the normal status, it will be shown as PJNN.

Note that if some pairs in the journal become suspended by error but the whole journal does not
become suspended, the status of other journals will not change

Miscellaneous troubleshooting