beautypg.com

Monitor logical path status – HP XP P9500 Storage User Manual

Page 79

background image

Description

Status

An operation for splitting or deleting the mirror is in progress.

Halting

Splitting a mirror changes the status in the following order: Halting, Halt, Stopping, and finally
Stopped.

Deleting a mirror changes the status in the following order: Halting, Halt, Stopping, Stopped,
and finally Initial.

An operation for splitting or deleting the mirror is in progress.

Halt

An operation for splitting or deleting the mirror is in progress.

Stopping

An operation for splitting or deleting the mirror is finished.

Stopped

A Cnt Ac-J delta resync pair has been created. It is ready for the delta resync operation.

Hold

A Cnt Ac-J delta resync pair is being created.

Holding

An error occurred with the Cnt Ac-J pair during the delta resync operation.

Hold(Failure)

This is the unused journal which is not registered data volumes.

Blank

Monitor logical path status

To view logical path status
1.

In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > DKC
Operation.

2.

In the Display box, select DKC and select LDKC.

3.

Locate the remote system in the list on the right side and view the Status column.

4.

To see in-depth path status, right-click the remote system and select DKC Status.

Description

Item

Number of the row.

No

Status of a logical path.

Path Status

Normal. The path is established and ready to use for copy operations.

Nothing. An operation for configuring or deleting the path is in progress.

Initialization Failed. An error occurred when the connection between local and remote
systems was initializing. The probable causes are:

- No cable is connected to the local system.

- No cable is connected to the remote system.

- No cable is connected to the network device between the two systems.

Communication Time Out. This status indicates one of the following:

- A timeout error has occurred between the primary and the secondary storage systems.

- A logic error is detected between the primary and the secondary storage systems.

Resource Shortage (Port). The local system rejected configuration of the logical path
connection. Logical path resources in the local system might be in use for other connections.

Resource Shortage (Pair-Port). The remote system rejected configuration of the logical path
connection. Logical path resources in the remote system might be in use for other connections.

Serial Number Mismatch. The serial number of the storage system connected to this logical
path does not match the serial number specified by the Add DKC dialog box.

Invalid Port. The port is not an initiator port.

Pair-Port Number Mismatch. Indicates one of the following:

- The specified port number is incorrect.

Monitor logical path status