beautypg.com

Specify number of volumes for initial copy, resync – HP XP P9500 Storage User Manual

Page 48

background image

6.

In the M-R Path box, define the Fibre Channel port used by logical path between local and
remote systems:
1.

In the Port, select a local system initiator port.

2.

In the Pair-Port, select the remote system RCU target port.

You may enter port numbers using the keyboard. You may abbreviate the number into
two characters. For example, “1A” may be entered instead of “CL1-A”. Letters may be
uppercase or lowercase.

7.

Click Set and close the Add Path dialog box.

8.

See the Preview list to check the settings that you have made.

If you want to modify a setting, select and right click the item in the Preview list and then
select Modify.

If you want to cancel a setting, select and right click the item and then select Cancel.

9.

Click Apply to apply the settings. If an error occurs, the error code appears in the rightmost
column of the Preview list. To view detailed information about the error, right click the error
code and select Error Detail.

Specify number of volumes for initial copy, resync

You can specify the number of volumes to be copied concurrently during an initial copy and
resynchronization operations.

48

Configuration operations