Table 19 RAID Manager error codes for Continuous Access Journal (continued)
Error content
Error code (SSB2)
Error code (SSB1)
A request of Cnt Ac-J pair create was rejected because the program product
of Cnt Ac-J was not installed.
8F39
The Cnt Ac-J pair cannot be created because cache CL2 is in abnormal
status.
8F46
The Cnt Ac-J pair cannot be created because cache CL1 is in abnormal
status.
8F47
The Cnt Ac-J pair cannot be created or resynchronized due to the following
contributing factors:
8F4D
•
Secondary journal is not registered.
•
Secondary journal volume is being blocked.
•
The specified S-VOL is being blocked.
A request of Cnt Ac-J Paircreate or Pairresync was received. However, the
operation cannot be performed because the load of the processing was
high. Wait about 5 minutes, then retry the operation.
8F50
A request of Cnt Ac-J Paircreate was rejected because the status of the
configuration could not be transited.
8F53
A request of Cnt Ac-J Paircreate or Pairresync was rejected because of the
one of following reasons.
8F58
•
The pair status of the specified S-VOL differed from the one of P-VOL.
•
The state of restore journal differed from the state of master journal.
A request of Cnt Ac-J Paircreate was rejected because the specified
secondary system did not support the external volume.
8F67
A request of Cnt Ac-J Paircreate was rejected because the specified volume
was a command device.
8F6D
The Cnt Ac-J pair cannot be created because the P-VOL is a volume for the
Just in Time function.
8F6E
The Cnt Ac-J pair cannot be created because the P-VOL is being used for
Snapshot.
8FEC
The information of the consistency group cannot be retrieved, because
Continuous Access Journal was not installed.
B992
The source of command devise has run out. Set to OFF the command device
and to ON again from the LUN Manager.
B9C0
Cnt Ac-J Paircreate cannot be performed because the specified device is a
command device.
B901
B9E1
Cnt Ac-J Paircreate cannot be performed because the mirror ID is invalid.
B902
B901/B9E0/B9E1/
B9E2/B9E4/D004
The command was rejected because the volume status was SMPL.
B907
The S-VOL hide mode is not supported.
B90A
Cnt Ac-J Paircreate cannot be performed because the Cnt Ac-J program
product is not installed.
B90D
Cnt Ac-J pair cannot be suspended because the mirror ID is invalid.
B909
A status of Cnt Ac-J pair was acquired at the time of unavailable to use the
Cnt Ac-J during the power-on. Retry the operation.
B900
The command was rejected because the Cnt Ac-J configuration was
changed. Check the status of the Cnt Ac-J pair.
B94B