beautypg.com

HP XP P9500 Storage User Manual

Page 116

background image

Table 19 RAID Manager error codes for Continuous Access Journal (continued)

Error content

Error code (SSB2)

Error code (SSB1)

A request to create or resynchronize a pair in the system that consists of
multiple primary and secondary systems was rejected because the Cont

EB28

Access Journal 3DC & 4x4 Open MF program product was not installed
in the secondary system.

A request to configure the system that consists of multiple primary and
secondary systems was rejected because the delta resync settings are
configured to the primary and secondary systems.

EB29

A request of Cnt Ac-J Paircreate for delta resync operation was rejected
because the specified Cnt Ac-J pair was used in the system that consists of
multiple primary and secondary systems.

EB2F

A request of Cnt Ac-J pair status transition was rejected because the specified
mirror ID was invalid.

EB30

The specified Cnt Ac-J pair cannot execute the takeover because the
specified Cnt Ac-J pair belongs to the journal that dedicated Cnt Ac-J and
Continuous Access Synchronous combination (2DC configuration).

EB45

A delta resync pair cannot be created due to one of the following reasons.

EB48

P-VOL of the Cnt Ac-J pair is different from P-VOL of the Continuous
Access Synchronous pair.

The serial number of the primary system that is recognized by P-VOL
and S-VOL is different.

A request of Cnt Ac-J Paircreate (journal suspend mode) was rejected
because the secondary system did not support the delta resync function.

EB49

A pair cannot be created because the restore journal was not registered.

EB4C

A pair cannot be created because the master journal was not registered.

EB4D

A request of Cnt Ac-J Paircreate was rejected because the specified S-VOL
was not mounted.

EB50

The Cnt Ac-J pair cannot be created because PIN data existed in the
specified S-VOL.

EB51

The Cnt Ac-J pair cannot be created because the specified S-VOL cannot
be accessed.

EB52

The Cnt Ac-J pair cannot be created because the specified S-VOL is blocked.

EB53

The command was rejected because the specified S-VOL was online from
the host.

EB57

The command was rejected because the specified journal volume or S-VOL
was reserved or being used in the storage system. Please check the status
of the volume.

EB58

The command was rejected because the specified S-VOL was being migrated
by Auto LUN. Please check the status of the volume.

EB59

The Cnt Ac-J pair cannot be created because the access attribute was set
to the specified P-VOL or S-VOL by the Data Retention.

EB5B

Cnt Ac-J pair cannot be resynchronized because an internal logical error
occurred.

EB5C

A request of Cnt Ac-J Paircreate was rejected because the state of S-VOL
was not SMPL.

EB5E

A request of Cnt Ac-J Paircreate was rejected because the program product
of Cnt Ac-J was not installed in the secondary system.

EB5F

116

Troubleshooting