HP XP P9500 Storage User Manual
Page 109
Table 19 RAID Manager error codes for Continuous Access Journal (continued)
Error content
Error code (SSB2)
Error code (SSB1)
HOLDTRNS status. Or, the Cnt Ac-J pair cannot be resynchronized (ALLJNL
parameter specifying), because the specified P-VOL is not in the either of
HOLD, HOLDTRANS, or NODELTA status.
A request of Cnt Ac-J Paircreate (journal suspend mode) or Cnt Ac-J
Pairresync (journal resync mode) was rejected because the status of the
370C
specified master journal or restore journal could not be transited, or the
status transition was in progress.
A request by Cnt Ac-J Paircreate or Cnt Ac-J Pairresync was rejected because
the Cnt Ac-J pair was in a status other than Suspending or was not used in
the 2DC configuration.
371C
The journal was registered when 2DC Cascade was set to Enable in the Edit
Journal Volume dialog box.
371D
In the 2DC Cascade configuration, the Cnt Ac-J pair cannot be created
when the Continuous Access Synchronous is in existence. Also, the 3DC
multitarget configuration cannot be created.
A request by Cnt Ac-J Paircreate or Pairresync was rejected because the
journal volume in the specified master journal was blocked.
3720
The Cnt Ac-J pair cannot be created because the version of the DKCMAIN
micro program on the remote storage system does not support the LUSE
volume.
3723
The Cnt Ac-J pair cannot be created because the volume specified as the
P-VOL was the system disk.
3726
A request of Cnt Ac-J Paircreate was rejected because it was connected
with the old model and the specified volume was unsupported.
3728
A request of Cnt Ac-J Paircreate was received. However, the pair could not
share the volume with Continuous Access Synchronous because the Cont
3729
Access Journal 3DC & 4x4 Open MF program product was not installed
in the primary system.
A pair cannot be created because the secondary system does not support
the combination of multiple primary and secondary systems.
372B
The volume is inaccessible because the primary volume is blocked.
372C
The specified volume is used in the system that consists of multiple primary
and secondary systems. Therefore the command was rejected because the
delta resync operation cannot be executed.
372D
A request to create or resynchronize a pair in the system that consists of
multiple primary and secondary systems was rejected because the Cont
372E
Access Journal 3DC & 4x4 Open MF program product was not installed
in the primary system.
Paircreate or Pairresync is not available, because the specified journal is
dedicated to the Cnt Ac-J-Continuous Access Synchronous combination
(2DC), and the MU# is 0.
8C13
The Cnt Ac-J pair cannot be created because the specified CTG number is
out of range of supporting.
8C19
The Cnt Ac-J pair cannot be created or resynchronized because the specified
journal number is incorrect.
8C1A
The Cnt Ac-J pair cannot be created because the specified journal number
is out of range of supporting.
8C1B
The request to update options was rejected because the specified journal
number or mirror ID is incorrect.
8C20
Troubleshooting using RAID Manager 109