beautypg.com

A error codes, Overview – HP Netserver L Server series User Manual

Page 149

background image

143

A Error Codes

Overview

FCArray Assistant classifies the events it records into five severity levels
described in the following table.

Table A-1. Severity Level Priorities and Descriptions

Severity

Type

Description

0

Critical

Controller failure.

1

Serious

The failure of a major component within
the array enclosure. For example, a
power supply, fan or physical drive.

2

Error

A consistency check fails, or a rebuild
on a drive stopped because of errors.

3

Warning

FCArray Assistant has failed to kill a
drive, or failed to start a rebuild.

4

Informational

Messages such as sign-ons and system
startups. When a consistency check or a
rebuild has finished, for example, or a
physical drive has been put on standby.

Critical (Level 0)

388

Controller is dead. System is disconnecting from this controller.

391

Controller is gone. System is disconnecting from this controller.

395

Controller is gone. System is disconnecting from this controller.

398

Controller is gone. System is disconnecting from this controller.

Serious (Level 1)

12

A hard disk has failed.

134

A logical drive has been made offline.

156

Bad data blocks found. Possible data loss.

256

Fan failure.

258

Fan failure.