A Error Codes
Overview
FCArray Assistant classifies the events it records into five severity levels
described in the following table.
Table A-1. Severity Level Priorities and Descriptions
Severity
Type
Description
0
Critical
Controller failure.
1
Serious
The failure of a major component within
the array enclosure. For example, a
power supply, fan or physical drive.
2
Error
A consistency check fails, or a rebuild
on a drive stopped because of errors.
3
Warning
FCArray Assistant has failed to kill a
drive, or failed to start a rebuild.
4
Informational
Messages such as sign-ons and system
startups. When a consistency check or a
rebuild has finished, for example, or a
physical drive has been put on standby.
Critical (Level 0)
388
Controller is dead. System is disconnecting from this controller.
391
Controller is gone. System is disconnecting from this controller.
395
Controller is gone. System is disconnecting from this controller.
398
Controller is gone. System is disconnecting from this controller.
Serious (Level 1)
12
A hard disk has failed.
134
A logical drive has been made offline.
156
Bad data blocks found. Possible data loss.
256
Fan failure.
258