• If the iSCSI Initiator is not listed under the Show Initiators command:
i.
Enter the initiator add command and add the iSCSI Initiator that is about to
do discovery.
ii.
Enable CHAP and enter a CHAP secret. For example:
CHAPsecret01
• If the iSCSI Initiator is already listed under the Show Initiators command:
i.
Enter the initiator mod command and select the iSCSI Initiator that is about to
do discovery.
ii.
Enable CHAP and enter a CHAP secret. For example:
CHAPsecret01
2.
Enable CHAP for the mpx100/100b iSCSI port:
• To enable CHAP for the mpx100/100b iSCSI port using the HP StorageWorks mpx Manager:
a.
Select the appropriate iSCSI port number.
b.
Click Advanced Configuration.
c.
Select the Enable CHAP check box.
d.
Enter a CHAP secret. For example:
hpstorageworks
• To enable CHAP for the mpx100/100b iSCSI port using the mpx100/100b CLI:
a.
Enter the set iscsi portnumber command.
b.
Select the Presented Target the initiator will log in to.
c.
Select the BiDi Discovery CHAP check box.
d.
Enter a CHAP secret. For example:
hpstorageworks
3.
Enable CHAP for the Microsoft iSCSI Initiator.
a.
Click the General tab.
b.
Click Secret in the middle of the screen.
c.
Click Reset.
d.
Enter the mpx100/100b iSCSI Presented Target CHAP secret. For example:
hpstorageworks
e.
Click OK.
f.
Click Discovery.
• For manually discovering iSCSI target portals:
i.
Click Add under Target Portals.
ii.
Enter the IP address of the iSCSI port of the mpx100/100b.
iii.
Click Advanced.
iv.
Select the CHAP Login Information check box.
v.
Enter the CHAP secret for the mpx100/100b discovered iSCSI Initiator in the Target
Secret box. For example:
CHAPsecret01
vi.
Select the Mutual Authentication check box.
vii.
Click OK.
viii.
Click OK and the initiator completes Target discovery.