Also, ensure the following two settings using Storage Navigator Modular or Storage Navigator
Modular2:
•
Set the data transfer speed of the external port to a fixed value other than Auto.
•
Set the data transfer speed of the target port of the HUS/AMS/WMS storage system to a
fixed value consistent with the data transfer speed of the external port.
Parameter Settings
Parameters
Window Names
Start Attribute
Boot Options
Specify when HUS/AMS/WMS is in a one-controller
configuration.
Single Mode
Specify when HUS/AMS/WMS is a two-controller
configuration.
Dual Active Mode
Optional
Delay Planned Shutdown
Optional
Drive blocking mode
HITACHI (default-do not change)
Vendor ID
DF600F (default-do not change)
Product ID
Optional
ROM Microprogram Version
Optional
RAM Microprogram Version
Optional
Option
System Parameter
Reset of occurred.
Operation if the processor failure
occurs
Optional
WEB Title
For AMS 1000, AMS 500, AMS 200 and WMS 100:
ON
Write and verify mode
For HUS 150, HUS 130, HUS 110, AMS 2500, AMS
2300, AMS 2100, and AMS 2010: OFF
Optional
Port Option
Port Options
Set AMS common setting to Standard Mode.
Host Connection Mode 1
Host Connection
Mode
Do not specify any parameters for AMS additional
settings.
Host Connection Mode 2
For AMS 1000, AMS 500, AMS 200 and WMS 100,
do not specify HISUP OFF mode.
Identifying the HUS/AMS/WMS model using the serial number
When the external storage system is HUS, AMS, or WMS, you can identify the storage system
model from the serial number displayed in the Serial Number column in the Volume Operation
window.
The following table describes the relationship between the number in the Serial Number column
and the storage system model.
Model
Displayed Serial Number
Storage System
HUS 150
95XXXXX
HUS
HUS 130
93XXXXX
HUS 110
91XXXXX
AMS 2500
87XXXXXX
AMS
HUS/AMS/WMS
65