beautypg.com

6-3 addhostrefresh, Addhostrefresh – HP StorageWorks XP10000 Disk Array User Manual

Page 85

background image

Command Line Interface Commands 85


Table 4-62

AddHostInfo Command Parameters

Parameter Name Status

Description

portwwn

Optional

Port WWN on the host bus adapter.

filetype

Optional

Type of the file System.

filename

Optional

Name of the file System.

size

Optional

LUN size in MB.

percentused

Optional

Percent of the LUN in use.

In this example, the CLI command specifies the following information for the host that connects to a LUN
(device number: 2, port number: 7, domain ID: 0) in a storage subsystem (serial number: 10001, model:
XP1024

):

Host name: MY_HOSTINFO_XP1024

Host IP address: 172.16.64.159

Mount point: C:

File system type: NTFS

File name: C:

SCSI bus number: 0

Host LUN: 1

HBA WWN: 11.22.33.44.55.66.77.88

LUN size: 10MB

LUN in use: 10%

Command execution example:

hdvmcli AddHostInfo -o "D:\logs\XP1024 AddHostInfo.log" serialnum=10001 model=XP1024

hostname=MY_HOSTINFO_XP1024 ipaddress=172.16.64.159 mountpoint=C: port=7 domain=0

devnum=2 osscsibus=0 osscsiid=15 oslun=1 portwwn=11.22.33.44.55.66.77.88 filetype=NTFS

filename=C: size=10 percentused=10

Command execution result:

RESPONSE:

An instance of HostInfo

objectID=HOSTINFO.MY_HOSTINFO_XP1024.0.15.1

name=MY_HOSTINFO_XP1024

serialNumber=10001

arrayType=HDS9980V

ipAddress=172.16.64.159

mountPoint=C:

portID=7

domainID=0

scsiID=15

lun=2

devNum=2

osScsiBus=0

osScsiID=15

osLun=1

portWWN=11.22.33.44.55.66.77.88

fileSystemType=NTFS

fileSystemName=C:

sizeInMB=10

percentUsed=10

lastUpdated=1039003476

4-6-3 AddHostRefresh

AddHostRefresh

refreshes the information about the hosts that Device Manager manages, which is obtained

from the Device Manager agent.

Users with access to this command: