6-3 addhostrefresh, Addhostrefresh – HP StorageWorks XP10000 Disk Array User Manual
Page 85
Command Line Interface Commands 85
Table 4-62
AddHostInfo Command Parameters
Parameter Name Status
Description
portwwn
Optional
Port WWN on the host bus adapter.
filetype
Optional
Type of the file System.
filename
Optional
Name of the file System.
size
Optional
LUN size in MB.
percentused
Optional
Percent of the LUN in use.
In this example, the CLI command specifies the following information for the host that connects to a LUN
(device number: 2, port number: 7, domain ID: 0) in a storage subsystem (serial number: 10001, model:
XP1024
):
•
Host name: MY_HOSTINFO_XP1024
•
Host IP address: 172.16.64.159
•
Mount point: C:
•
File system type: NTFS
•
File name: C:
•
SCSI bus number: 0
•
Host LUN: 1
•
HBA WWN: 11.22.33.44.55.66.77.88
•
LUN size: 10MB
•
LUN in use: 10%
Command execution example:
hdvmcli AddHostInfo -o "D:\logs\XP1024 AddHostInfo.log" serialnum=10001 model=XP1024
hostname=MY_HOSTINFO_XP1024 ipaddress=172.16.64.159 mountpoint=C: port=7 domain=0
devnum=2 osscsibus=0 osscsiid=15 oslun=1 portwwn=11.22.33.44.55.66.77.88 filetype=NTFS
filename=C: size=10 percentused=10
Command execution result:
RESPONSE:
An instance of HostInfo
objectID=HOSTINFO.MY_HOSTINFO_XP1024.0.15.1
name=MY_HOSTINFO_XP1024
serialNumber=10001
arrayType=HDS9980V
ipAddress=172.16.64.159
mountPoint=C:
portID=7
domainID=0
scsiID=15
lun=2
devNum=2
osScsiBus=0
osScsiID=15
osLun=1
portWWN=11.22.33.44.55.66.77.88
fileSystemType=NTFS
fileSystemName=C:
sizeInMB=10
percentUsed=10
lastUpdated=1039003476
4-6-3 AddHostRefresh
AddHostRefresh
refreshes the information about the hosts that Device Manager manages, which is obtained
from the Device Manager agent.
Users with access to this command: