HP StorageWorks XP10000 Disk Array User Manual
Page 20
Command Line Interface Commands 20
Table 4-1
Extracting Parameter Values
To Find This Parameter Value: Do This:
lun
Execute the GetStorageArray (subtarget=HostStorageDomain,
hsdsubinfo=freelun)
command, specifying only the model and serialnum
parameters, HostStorageDomain for the subtarget parameter, and freelun for the
hsdsubinfo
parameter. Use one of the lun values.
lungroupid
Execute the GetStorageArray (subtarget=Port, portsubinfo=LUNGroup)
command, specifying only the model and serialnum parameters, and LUNGroup for the
portsubinfo
parameter. Use the objectID value that appears under An instance
of LUNGroup
.
lusedevnums
Execute the GetStorageArray (subtarget=LDEV) command. Use the devNum value
of the LDEV for which path=false and onDemandDevice=false. Be sure that the
LDEVs have the same emulation, sizeInKB, and raidType attributes, specifying
them in the form of a comma-delimited list.
mastercontrollerid
Execute the GetReplicationControllerPair command without specifying any
parameters, and then obtain the value from the execution result.
masterserialnum
Execute the GetReplicationControllerPair command without specifying any
parameters, and then obtain the value from the execution result.
model
Execute the GetStorageArray command. Use the displayArrayType value that
appears under An instance of StorageArray.
nickname
Execute the GetStorageArray (subtarget=Port) command, specifying only the
model
and serialnum parameters, Port for the subtarget parameter, and
HostStorageDomain
for the portsubinfo parameter. The nickname value is
displayed under An instance of HostStorageDomain.
objectid
Execute the GetStorageArray command, setting the subtarget corresponding to the
desired component, and then obtain the value from the execution result.
pdevid
Execute the GetStorageArray (subtarget=PDEV) command, specifying only the
model
and serialnum parameters, and PDEV for the subtarget parameter. The
objectID
value that appears under An instance of PDEV consists of four parts, with
adjoining parts separated by a dot. Use the right-most value of objectID to specify the
pdevid
parameter.
pdevnums
Execute the GetStorageArray (subtarget=PDEV) command, specifying only the
model
and serialnum parameters, and PDEV for the subtarget parameter. In the
execution result of this command, the objectID value that appears in a PDEV consists of
four parts, with adjoining parts separated by a dot. Enter the right-most value for the
pdevnums
parameter. If there is more than one such value specified, separate them with
a comma.
port
Execute the GetStorageArray (subtarget=Port) command, specifying only the
model
and serialnum parameters, and the value for subtarget=Port. The portID
value appears under An instance of Port.
pvoldevnum
Execute the GetHost command, and then obtain the value from the execution result.
pvolserialnum
Execute the GetHost command. The pvolSerialNum is displayed as An instance
of ReplicationInfo
.
remoteserialnum
Execute the GetReplicationControllerPair command without specifying any
parameters, and then obtain the value from the execution result.
remoteSSID
Execute the GetReplicationControllerPair command without specifying any
parameters, and then obtain the value from the execution result.
replicationgroupid
Execute the GetHost command, and then obtain the value from the execution result.
serialnum
Execute the GetStorageArray command, and then use the serialNumber value.
source
Execute the GetAlerts command, and then obtain the value from the execution result.
svoldevnum
Execute the GetHost command, and then obtain the value from the execution result.
svolsequencenum
Execute the GetStorageArray command for the storage subsystem that contains the S-
VOL. Use the value of the sequenceNumber.