HP StorageWorks XP10000 Disk Array User Manual
Page 101
Command Line Interface Commands 101
Table 4-78
AddReplication Command Parameters
Parameter Name
Status
Description
groupname
Optional
Specify the group name used in the RAID Manager. The maximum
number of characters you can use to specify a group name is 31.
The group name cannot begin with a number sign (#) or a hyphen
(-).
NOTE:
If the replicationgroupid parameter is specified, this
parameter is ignored.
pvolhostid
Required (Method 2 or 3) If you are using method 2 or 3, specify the ID of the host that
recognizes the primary volume (P-VOL).
NOTE:
If the replicationgroupid parameter is specified, this
parameter is ignored.
pvolinstancenum
Required (Method 2)
Specify the number of the Continuous Access XP instance that
manages P-VOL.
NOTE:
If the replicationgroupid parameter is specified, this
parameter is ignored.
pvolportnum
Required (Method 3)
If you are using method 3, specify the port number of the
Continuous Access XP instance that manages P-VOL.
In Solaris™, specify an integer from 0 to 65535.
In AIX
®
, Windows
®
, HP-UX, and Linux
®
, specify an integer from
1
to 65535.
NOTE:
If the replicationgroupid or pvolinstancenum
parameter is specified, this parameter is ignored.
svolhostid
Required (Method 2 or 3) If you are using method 2 or 3, specify the ID of the host that
recognizes the secondary volume (S-VOL).
NOTE:
If the replicationgroupid parameter is specified, this
parameter is ignored.
svolinstancenum
Required (Method 2)
Specify the number of the Continuous Access XP instance that
manages S-VOL.
NOTE:
If the replicationgroupid parameter is specified, this
parameter is ignored.
svolportnum
Required (Method 3)
If you are using method 3, specify the port number of the
Continuous Access XP instance that manages S-VOL.
In Solaris™, specify an integer from 0 to 65535.
In AIX
®
, Windows
®
, HP-UX, and Linux
®
, specify an integer from
1
to 65535
NOTE:
If the replicationgroupid or svolinstancenum
parameter is specified, this parameter is ignored.
pvolarraytype
Required
Specify the model of the storage subsystem that contains P-VOL.
pvolserialnum
Required
Specify the serial number of the storage subsystem that contains
P-VOL.
pvoldevnum
Required
Specify the device number of P-VOL.
pvolportid
Optional
Specify the port ID in the Continuous Access XP configuration file
that manages P-VOL paths.
svolarraytype
Required
Specify the model of the storage subsystem that contains S-VOL.
svolserialnum
Required
Specify the serial number of the storage subsystem that contains S-
VOL.
svoldevnum
Required
Specify the device number of S-VOL.
svolportid
Optional
Specify the port ID in the Continuous Access XP configuration file
that manages S-VOL paths.