5-3 addwwnforhoststoragedomain, Addwwnforhoststoragedomain – HP StorageWorks XP10000 Disk Array User Manual
Page 74
Command Line Interface Commands 74
hdvmcli AddLunGroup -o "D:\logs\XP512 AddLunGroup.log" "serialnum=10001" "model=XP512"
"port=19" "groupelements=PATH.HDS9960.10001.16.2.0,PATH.HDS9960.10001.16.2.1"
"nickname=hp" "name=hp"
Command execution result:
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 Port elements:
An instance of Port
.
. (Attributes of Port are omitted here)
.
List of 1 LUNGroup elements:
An instance of LUNGroup
objectID=LUNGROUP.HDS9960.10001.0.19.hp
name=hp
nickname=hp
List of 2 Path elements:
An instance of Path
objectID=PATH.HDS9960.10001.16.2.0
devNum=0
portID=19
domainID=16
scsiID=15
LUN=8
wwnSecurityValidity=true
.
. (repeated for other Path instances)
.
4-5-3 AddWWNForHostStorageDomain
AddWWNForHostStorageDomain
secures LUNs in a host storage domain by assigning one or more WWNs
to it (see
Table 4-48
).
Users with access to this command:
•
Yes: System Administrator, Storage Administrator, Local System Administrator, Local Storage
Administrator
•
No: Guest, Local Guest
•
Restricted to permitted resources: Local System Administrator and Local Storage Administrator do not
have access range limitations.
NOTE:
When AddWWNForHostStorageDomain secures LUNs in a host storage domain, LUN security is
automatically enabled.
Table 4-48
AddWWNForHostStorageDomain Command Parameters
Parameter Name Status
Description
serialnum
Required Serial number of the storage array for the Host Storage Domain.
model
Required Model of the storage array for the Host Storage Domain.
port
Required Port ID of the Host Storage Domain.
domain
Required Domain ID of the Host Storage Domain.
wwn
Required Comma-separated list of WWN to secure the Host Storage Domain.
Command execution example:
hdvmcli AddWWNForHostStorageDomain -o "D:\logs\XP1024 AddWWNForHostStorageDomain.log"
"serialnum=10001" "model=XP1024" "port=1" "domain=1"