beautypg.com

Accton Technology VS4512DC User Manual

Page 56

background image

Configuring the Switch

3-26

Command Attributes

Authentication

– Select the authentication, or authentication sequence

required:
- Local – User authentication is performed only locally by the switch.
- Radius – User authentication is performed using a RADIUS server only.
-

TACACS

– User authentication is performed using a TACACS+ server only.

-

[authentication sequence]

– User authentication is performed by up to three

authentication methods in the indicated sequence.

• RADIUS Settings

- Server IP Address – Address of authentication server. (Default: 10.1.0.1)
- Server Port Number – Network (UDP) port of authentication server used for

authentication messages. (Range: 1-65535; Default: 1812)

- Secret Text String – Encryption key used to authenticate logon access for

client. Do not use blank spaces in the string. (Maximum length: 20 characters)

- Number of Server Transmits – Number of times the switch tries to

authenticate logon access via the authentication server.
(Range: 1-30; Default: 2)

- Timeout for a reply – The number of seconds the switch waits for a reply

from the RADIUS server before it resends the request.
(Range: 1-65535; Default: 5)

• TACACS Settings

- Server IP Address – Address of the TACACS+ server. (Default: 10.11.12.13)
- Server Port Number – Network (TCP) port of TACACS+ server used for

authentication messages. (Range: 1-65535; Default: 49)

- Secret Text String – Encryption key used to authenticate logon access for

client. Do not use blank spaces in the string. (Maximum length: 20 characters)

Note: The local switch user database has to be set up by manually entering user names

and passwords using the CLI. (See “username” on page 24.)