beautypg.com

Efm interleave – Accton Technology VS4512DC User Manual

Page 252

background image

Command Line Interface

4-106

efm interleave

This command sets the interleave parameters for the selected VDSL port.

Syntax

efm interleave [downstream M value] [upstream M value]

[downstream I value] [upstream I value]

no efm interleave

M value – M is the interleaving depth index. Range: 0-64
I value – I is the interleaving block length. Range: 4 or 8

Default Setting

• M – The interleaving depth index.

Upstream default value: 8, Downstream default value: 16

• I – The interleaving block length.

Upstream default value: 8, Downstream default value: 8

Command Mode

Interface Configuration

Command Usage

Interleaving improves Reed Solomon error correction when there is pulse
noise. A greater degree of interleaving will provide more protection against
pulse noise but will increase transmission delay and reduce the effective
bandwidth of the link. The degree of interleaving can be increased by
increasing M or I.

Example
The following example configures VDSL port 1 with:

• M - downstream value: 16, Upstream value: 8
• I - downstream value: 8, Upstream value: 8

Related Commands

efm noise-margin (4-107)
show controllers efm status (4-114)

Console#config
Console(config)#interface ethernet 1/1
Console(config-if)#efm interleave 16 8 8 8
Console(config-if)#end
Console#show controllers efm status link Ethernet 1/1
Interface Link SNR (dB) RS Errs Interleaver
DS1 DS2 US1 US2 DS.M DS.I US.M US.I PBO
------------- ---- -------------------- -------- ------------------- ---
Ethernet 1/1 Up 43.0 35.0 45.0 43.0 0 16 8 8 8 on
Console#

This manual is related to the following products: