beautypg.com

Efm rate-adapt – Accton Technology VS4512DC User Manual

Page 254

background image

Command Line Interface

4-108

Example
The following example configures VDSL port 1 with an upstream noise margin of 6,
and a downstream noise margin of 6.

Related Commands

efm interleave (4-106)
show controllers efm-noise-margin (4-116)

efm rate-adapt

This command enables and disables the rate adaption feature on the selected VDSL
port.

Syntax

efm rate-adapt
no efm rate-adapt

Default Setting

Disabled

Command Mode

Interface Configuration

Command Usage

The data rate on a VDSL line can be affected by factors such as temperature,
humidity, and electro-magnetic radiation. When rate adaption is enabled, the
switch will determine the optimal transmission rate for the current conditions.

Example
The following example shows rate adaption enabled for port 1.

Related Commands

rate-limit (4-97)

A6-22-3A

26

10

17

10

A7-40-5A

32

23

17

Not Used

A8-46-7A 35

26

23

14

TLAN 32

10

29

10

Max-Rate 41

41

41

41

Console(config)#interface ethernet 1/1
Console(config-if)#efm noise-margin 6 6
Console(config-if)#end

onsole#config
Console(config)#interface ethernet 1/1
Console(config-if)#efm rate-adapt
Console(config-if)#

Profile Name

Theoretical Minimum Signal-to-Noise Ratio (dB)

DS1

DS2

US1

US2