Window "log, 3 window "log – NORD Drivesystems BU0000 User Manual
Page 55
Macro editor
55
BU 0000 GB
Type
Description
Value 23 (32bit)
The 2nd and 3rd set point and/or actual value are to be used as a 32bit value.
Note:
For this configuration the device must be accordingly configured accordingly (see „ Set point
and/or actual value formatting").
Formatting of Set point and/or actual value
Formatting
Description
Normiert
This formatting interprets the set point and/or actual value as 16 bits standardized value.
Normalization means a scaling of the range of values and lies between -200% and 199% of a
base value (e.g. nominal frequency).
Unnormiert
IIn this formatting the set point or actual value is interpreted as 16 bits value, which is indicated
without scaling.
Lowword (32bit) This formatting specifies, that the first value is the Low word and the 2nd value is the High
word value 12 (32bit). This value can be selected only with the 32bit types.
Highword (32bit) This formatting specifies, that the first value is the high word and the 2nd value is the low word
value 12 (32bit). This value can be selected only with the 32bit types.
Note:
Please consider that the configuration of the device must be identical to the settings.
8.1.3 Window "Log"
All events of the scheduler are stored in log. In order to indicate logs, one must open over the menu entry
„View->Log" the view „Log". The window is likewise a tool window and can to the edge of the main window
be docked or undocked. In the window all log entries in a sorted list are represented. Here the last entry is
in at the beginning of the list.
Name of action
Description
Delete
The action deletes the list.
Save
The action stores the entries into a file.