Starting address
In this field, the USS address can be defined, from where the search run of NORD CON starts
to find connected devices. All frequency inverters with lower address cannot be found by NORD
CON.
End address
In this field, the user can define the USS address for the ending of the search for connected
devices. All inverters with a higher address number cannot be found by NORD CON.
Stop all connected devices
With the action, the user can activate or deactivate the stopping (disable) of connected
devices. When this function is active, all enabled devices are stopped if the interface of the
device is programmed to "bus".
Automatic device search after start of program
With this action the user can activate or deactivate the automatic device search after start of
the program. When this function is active, NORD CON automatically starts the bus scan after
the program is started.
Attention
All changes are only available if the user push the button "apply". With the button "Restore"
then user can undo all changes.