NORD Drivesystems BU0000 User Manual
Page 50
NORD CON Manual
50
BU 0000 GB
The trigger starts the measurement. First choose the
source of trigger
. Trigger sources can be
measurement values, digital inputs, status of inverter, etc. The starting conditions are defined
by
trigger level
resp.
trigger edge
.
ATTENTION
The increments of the trigger levels are different depending on the trigger source. Therefore
not every value can be set. After starting a recording, the closest possible values is calculated
and set.
Time between two measured values is set by
sampling rate
. Numbers of
measured value
s and
sampling rate define the
time of sampling
.
The
Pre-trigger/Delay
set the beginning of the measurement in relation to the trigger event.
Note:
The dynamic of measured values defines the best rate of sampling: fast changing values need
a low sampling rate. The number of measured values defines the time of sending the values
from inverter to
NORD CON
.
3. Sampling modes
The oscilloscope has 2 differently modes. The user can choose between "Single" and "Roll"
mode. The "Single" mode is the standard mode. In this mode starts a recording with the current