beautypg.com

Types of set point and/or actual value – NORD Drivesystems BU0000 User Manual

Page 54

background image

NORD CON Manual

54

BU 0000 GB

Object

Parameter

Description

Decimale

Hexadecimale

Binary

Set point
and Actual
values

Node ID

The parameter specifies the USS address of the desired device.

Note:

Since the current control word cannot be read from the device, when starting scheduler
the control word is set to 0.

Type

The parameter specifies the type of a value (see actual setpoint and actual value
types).

Format

The parameter specifies formatting from set point and/or actual values (see set point
and actual value of formatting").

Resolution

The parameter specifies the resolution to set point and/or actual values. It is used only
for the display in the editor.

Display
format

The parameter specifies the display format in the view „variables ". It can be selected
between the following representations:

Decimal

Hexadecimal

Binary

Parameter Node ID

The parameter specifies the USS address of the device.

ParamNo

The value specifies the number of the parameter.

Subindex

The value specifies the Subindex of the parameter.

Resolution

The parameter specifies the resolution to set point and/or actual values. It is used only
for the display in the editor.

Data type

The value specifies the data type of the parameter. In the current devices only 2 data
types are used (16 bits Integer and 32 bits Integer).

Display
format

The parameter specifies the display format in the view „variables ". It can be selected
between the following representations:

Decimal

Hexadecimal

Binary

Types of set point and/or actual value

Type

Description

Value 1 (16bit)

The 1.2 and/or 3 set point and/or actual value is to be used.

Value 12 (32bit)

The first and second set point and/or actual value is to be used as a 32bit value.

Note:

For this configuration the device must be accordingly configured accordingly (see „ Set point
and/or actual value formatting").

Value 13 (32bit)

The 1st and 3rd set point and/or actual value are to be used as a 32bit value.

Note:

For this configuration the device must be accordingly configured accordingly (see Set point
and/or actual value formatting ").