TECHNICAL DATA

74

IFC 050

www.krohne.com

08/2013 - 4002184002 - MA IFC 050 R02 en

Electrical connection

General

Electrical connection is carried out in conformity with the VDE 0100 directive

"Regulations for electrical power installations with line voltages up to 1000 V" or

equivalent national specifications.

Power supply

100…230 VAC (-15% / +10%), 50/60 Hz;

240 VAC + 5% is included in the tolerance range.

24 VDC (-30% / +30%)

Power consumption

AC: 15 VA

DC: 5.6 W

Signal cable

Only necessary for remote versions.

DS 300 (type A)

DS 300 (type A)

DS 300 (type A)

DS 300 (type A)

Max. length: 600 m / 1950 ft (depending on electrical conductivity and measuring

sensor version)

Cable entries

Standard: M20 x 1.5 (8...12 mm)

Option: ½ NPT, PF ½

Outputs

Basic

All outputs are electrically isolated from each other and from all other circuits.

All operating data and output values can be adjusted.

Description of abbreviations

U

ext

= external voltage; R

L

= load + resistance;

U

o

= terminal voltage; I

nom

= nominal current