4.8 Overview of outputs

4.8.1 Description of the CG number

4.8.2 Fixed, non-alterable output versions

This signal converter is available with various output combinations.

• The grey boxes in the tables denote unassigned or unused connection terminals.
• In the table, only the final digits of the CG no. are depicted.
• Terminals D- and A- are connected for active pulse/frequency output (no galvanic isolation

anymore).

• Available are an active or passive pulse/frequency output, or the active or passive status/limit

output. It's not possible to use both at the same time!

Basic outputs (I/Os)

Modbus (I/O) (option)

Description of used abbreviations

Figure 4-10: Marking (CG number) of the electronics module and output variants

1 ID number: 1
2 ID number: 0 = standard; 9 = special
3 Power supply
4 Display (language versions)
5 Output version

CG no.

Connection terminals

S

D-

D

D+

A-

A

A+

1 0 0

R 0 0

1

P

p

/ S

p

passive

I

p

+ HART

®

passive

2

connected to

A-

P

a

active

connected to

D-

I

a

+ HART

®

active

2

P

p

/ S

p

passive

I

a

+ HART

®

active

2

1 Shielding
2 Function changed by reconnecting

CG no.

Connection terminals

B-

B

B+

S

R 0 0

Sign. A (D0-)

Common

Sign. B (D1+)

Shielding

I

a

I

p

Current output active or passive

P

a

P

p

Pulse/frequency output active or passive

S

a

S

p

Status output/limit switch active or passive