Operation, 2 menu b, test – KROHNE IFC 050 Converter EN User Manual
Page 52

6
OPERATION
52
IFC 050
www.krohne.com
08/2013 - 4002184002 - MA IFC 050 R02 en
6.4.2 Menu B, test
No.
Function
Setting / Description
B1 simulation
B1.1
volume flow
mass flow
Depending on the selection, simulation of the volume or mass flow
according to the following sequence:
Select:
set value /
break (exit function without simulation)
Query: start simulation?
Select:
no (exit function without simulation) / yes (start simulation)
B1.2
current output A
simulation X
[X stands for one of the connection terminals A or D]
Sequence and settings similar to B1.2, see above!
For pulse output a set number of pulses are output in 1 s!
B1.3
pulse output D
B1.3
frequency out X
B1.3
limit switch D
B1.3
status output D
B2 actual values
B2.1
operating hours
Display the actual operating hours; exit the displayed function with key ^.
B2.2
act. flow speed
Display the actual flow speed; exit the displayed function with key ^.
B2.3
electr. temperature
Display the actual electronics temperature; exit the displayed function with
key ^.
B2.4
act. coil resistance
Display the actual resistance of the field coils.
B3 information
B3.1
C number
This number clearly identifies the electronics.
B3.2
Electronic Revision ER
Reference identification number, electronic revision and production date of
the device; includes all hardware and software changes
B3.3
device serial no.
Serial no. of the system.
B3.4
electronic serial no.
Serial no. of the electronics