ELECTRICAL CONNECTIONS

30

IFC 050

www.krohne.com

08/2013 - 4002184002 - MA IFC 050 R02 en

• To open the cover of the electrical terminal compartment, lightly press in the side walls of the

mains cover 2.

• Flip the mains cover up.
• Connect the power supply.
• Close the mains cover again by flipping it down.

100...230 VAC (tolerance range: -15% / +10%)

100...230 VAC (tolerance range: -15% / +10%)

100...230 VAC (tolerance range: -15% / +10%)

100...230 VAC (tolerance range: -15% / +10%)

• Note the power supply voltage and frequency (50...60 Hz) on the nameplate.

24 VDC (tolerance range: -30% / +30%)

24 VDC (tolerance range: -30% / +30%)

24 VDC (tolerance range: -30% / +30%)

24 VDC (tolerance range: -30% / +30%)

• Note the data on the nameplate!
• When connecting to functional extra-low voltages, provide a facility for protective separation

(PELV) (acc. to VDE 0100 / VDE 0106 and/or IEC 364 / IEC 536 or relevant national
regulations).

Figure 4-9: Terminal compartment for power

1 Cable entry for power supply
2 Mains cover
3 Ground terminal
4 100...230 VAC (-15% / +10%)
5 24 VDC (-30% /+30%)

INFORMATION!
240 VAC + 5% is included in the tolerance range.