Electrical connections, 5 connecting the signal and field current cables – KROHNE IFC 050 Converter EN User Manual
Page 27
ELECTRICAL CONNECTIONS
4
27
IFC 050
www.krohne.com
08/2013 - 4002184002 - MA IFC 050 R02 en
4.5 Connecting the signal and field current cables
4.5.1 Connecting the signal and field current cables to the signal converter, remote
version
Connect the electrical conductors as follows:
1 Press with a screwdriver in the slot on the spring terminal.
2 Insert the electrical conductor into the plug.
3 The conductor will be clamped as soon as the screwdriver is pulled out of the slot.
DANGER!
Cables may only be connected when the power is switched off.
DANGER!
The device must be grounded in accordance with regulations in order to protect personnel
against electric shocks.
WARNING!
Observe without fail the local occupational health and safety regulations. Any work done on the
electrical components of the measuring device may only be carried out by properly trained
specialists.
INFORMATION!
The compact version is supplied preassembled from the factory.
Figure 4-7: Connecting the signal and field current cables
1 Cable entry for field current cable
2 Cable entry for signal cable
3 Electrical conductor (7)
4 Electrical conductor (8)
5 Connecting the field current cable shield
6 Stranded drain wire (1) of the inner shield (10) of the signal cable
7 Electrical conductor (2)
8 Electrical conductor (3)
9 Stranded drain wire (S) of the outer shield (60)